Update from Elliott 7 to 8 Gives an Error that the Drive Letter Does Not Match

Update from Elliott 7 to 8 Gives an Error that the Drive Letter Does Not Match

Release Date: 12/30/22
Version: 8.0 and Above

After an update from Elliott 7 to Version 8, I get an error that the drive letter does not match.



The issue may stem from the Tutorial company.  If the company was never used in Version 7, it may still contain the default drive letter of C:.  Elliott 8 will use the first company listed to determine the data drive letter and they may conflict with the drive letter configured in the shortcut.  You can log into Elliott as SUPERVISOR and a prompt will appear to allow you to change the drive letter or you can simply rename or remove the TUTORIAL folder if it will not be used.

MAD




    • Related Articles

    • Windows 1809 Update Causes Map Drive to Disconnect After Log Out

      Release Date: 12/5/2018 It has been brought to our attention that the latest Windows 1809 update can cause the map drive to disconnect, which may stop Elliott Business Software from running. This problem applies to both Windows 10 and Windows 2019 ...
    • Mapped Local Drive Disconnected to Cause Label Printing Error

      Q - We use remote desktops, and we print our CSV label files to our remote workstation local drive. The CSV file will then be picked up by the label printing software bartender and printed on the connected local label printer. We mapped our W: drive ...
    • How to Map Local Drive in Remote Desktop to Print Label at Remote Warehouse

      Release Date: 8/8/2018 For Elliott users who have a remote warehouse, the easiest solution to let warehouse users have access to Elliott is to let them use a remote desktop to login to the terminal server hosted at the user's location. While the ...
    • Btrieve Error Codes 001 - 199

      MicroKernel (Btrieve) Database Engine Status Codes This section describes status codes that the MicroKernel returns. All status codes are provided in 3-digit formats since the search on this website cannot search 1 or 2-digit words correctly. That is ...
    • Cannot Create DDFs Due to Metadata Version Mismatch

      Release Date: 11/28/2022 Version: 8.5 or Higher Q - We recently upgraded to Actian PSQL 15. I wanted to create a new ODBC database. So I go to PSQL Control Center, right click on the "Database" node and choose "New" to create the database, but it is ...