Ping Test to Isolate Inconsistent Load Error 198

Ping Test to Isolate Inconsistent Load Error 198

Release Date: 06/27/17

Q - We have an error that only occurs occasionally. The error code that goes with is 198.  The following is a sample:

    Load error: file 'POEDADD1'
    error code: 198, pc=5344, call=58, seg=0




This error seems to occur on only one computer and only in the purchasing module. Do you have suggestions about steps I can take to resolve this? Re-install Pervasive? Check the PC’s network connection?

A - Error 198 is a typical error indicating that the network connection is unstable. To isolate the network components that cause this error, you can run a simple test to “Ping” the server from the workstation continually for 5 minutes, then see the results.

1. At command prompt, type Ping –t Server_Name (e.g. Ping –t TS4). The system will continue to ping without stopping.  See example below:



2. After 5 minutes, use Ctrl+C key to stop pinging.

3. Check results at the bottom. For example: Sent = 1000, Received = 990, Lost = 10 (1% loss).  If you have any percentage lost,  then you know the network connection is not stable. After that, you can start changing network components one by one until you isolate this issue.  You can start from the easiest to the hardest. For example:
  • If there is an extra connection on the network switch, then switch this workstation's network cable to the other empty connection first.  Then perform the same ping test to see if this improves the situation.
  • Change the network cable.  Generally speaking, you should use a CAT-6 cable Gigabits Ethernet.  Some people use a CAT-5 cable that has higher resistance.  Get a new CAT-6 cable and connect the workstation directly to the network switch.
  • Switch another workstation to this location and use the old Ethernet to test.
  • If the connection is to a separate small Ethernet switch, consider replacing that Ethernet switch.
  • If there's an extra Ethernet connect at the workstation, try the other connection.
  • Replace the Ethernet connection at the workstation.
For additional load error 198 information, see the following Knowledge Base article:


RSS



    • Related Articles

    • What Causes Load Error 198?

      Modified Date: 6/7/2019 Q - One of our computers received an error 198 load error randomly. The message looked like the following sample screen: Load error: file "SYCONSEL" error code: 198, pc=0, call=15, seq=0 or Load error: file "SYACTCHK" error ...
    • Inconsistent Elliott Error on Terminal Server

      Q - We occasionally run into an issue with our terminal server where Elliott crashes after entering the username/password. After clicking on the shortcut, it prompts for the username / password. After clicking OK, it crashes. We are confused because ...
    • Inconsistent File Name in Btrieve Error Window

      Release Date: 09/11/20 Version: 7.x - 8.5 Q - I notice that sometimes in a Btrieve Error window, the physical file and the file name are not consistent. Take, for example, the following error message: EL850P: Btrieve Error 067 on NSCTLFIL COP Control ...
    • Elliott Was Unable to Load the Following Module: EL800B.LBR

      Release Date: 03/20/2019 Q - When users attempt to log on to Elliott on the terminal server, the following error message shows up: ********************************************************** Elliott was unable to load the following module: EL800B.LBR ...
    • Inconsistent Error with Sending PDF PostOffice Email Due to Volume (Mass Email)

      Release Date: 03/05/2019 Version: 8.2 and up Q - We are experiencing ongoing inconsistent issues with emailing PDF PostOffice invoices through the Printing Duplicate Invoices application. Below is an example of the error: ERROR: Failure sending mail. ...