Elliott Was Unable to Load the Following Module: EL800B.LBR

Elliott Was Unable to Load the Following Module: EL800B.LBR

Release Date: 03/20/2019

Q - When users attempt to log on to Elliott on the terminal server, the following error message shows up:
**********************************************************
Elliott was unable to load the following module:
  EL800B.LBR


Elliott will terminate now...
**********************************************************  
See sample screen below. Please assist.


A - Make sure your Elliott shortcut is using a mapped drive and not the local path or UNC path. Sometimes, if you lose the network drive for some reason, it can cause this to happen. 

If you are running Elliott V7, you will see a similar message with EL700B.Lbr.

If you are running Elliott V8.5, you will see a similar message with EL850B.Lbr.

The user later responded that the problem was resolved after they rebooted the terminal server.

EMK


    • Related Articles

    • What Causes Load Error 198?

      Modified Date: 6/7/2019 Q - One of our computers received an error 198 load error randomly. The message looked like the following sample screen: Load error: file "SYCONSEL" error code: 198, pc=0, call=15, seq=0 or Load error: file "SYACTCHK" error ...
    • Btrieve Error Codes 001 - 199

      MicroKernel (Btrieve) Database Engine Status Codes This section describes status codes that the MicroKernel returns. All status codes are provided in 3-digit formats since the search on this website cannot search 1 or 2-digit words correctly. That is ...
    • Elliott V8.0 Report Viewer Received "Specified File Does Not Exist" Message

      Q - We implemented the suggested NTFS security on Elliott V8 based on the following Knowledge Base article: https://support.netcellent.com/portal/en/kb/articles/elliott-8-directory-structure-and-ntfs-rights-23-10-2024 Now when a non-admin user prints ...
    • Elliott Synchronizing to Local Error

      Release Date: 09/16/2020 Version: 8.5 & Up Q - The following error occurred while logging into Elliott after the live update. Before logging in, I was completely backed out at the time. Elliott Synchronizing to Local Error We were unable to ...
    • Unable to Run Elliott from UNC Path

      Q - I am trying to set up a workstation to run Elliott. I installed the PSQL 11 client already. When I browse the PSQL server to where Elliott resides and click on the EL700.EXE to start Elliott, I receive the following error message: Unable to load ...